AC Maintenance in Denver, CO

Tell us about the job

Takes about a minute. No obligation.

Tune-up, service, or cleaningCentral ACDenver County, CO
Step 1 of 2

What ZIP code is the job in?

Three months of real work

Your AC runs June through August here, with afternoon highs averaging 87°F. That's the stretch it has to hold up without a problem. One visit before June covers it.

Spring is the time to catch problems

Hail and wind hit this county often enough that a coil or a fan blade can take damage without you noticing right away. A check before summer catches that before the heat does.

3 months
June through August, your air conditioner is on duty
87°F
the average summer afternoon it cools against
142 hail events
in ten years, and hail bends the fins on outdoor coils
64 wind events
in ten years, and wind drives debris into outdoor units
Isometric cutaway illustration of a house showing interior ductwork, an air handler, and an outdoor condenser unit connected by lines, with simple furniture in the rooms.
Your air conditioner works hardest from June through August.

NOAA nClimDiv, 1991–2020 normals

Denver County AC starts its three-month run in June.

May is the month to get it checked, before it has to work.

One summer's worth of heat doesn't call for more than one visit

Power costs 14.92 cents a kWh statewide
Cooling runs June through August
Summer afternoons average 87°F

Keep the yearly check

Once a year is enough here.

Find a contractor
A man in a dark shirt and tan work pants, seen from behind, carries a worn canvas tool bag up concrete steps toward a red front door, with a potted evergreen shrub beside the entry.
A gray metal air conditioning condenser unit mounted on a concrete pad in a flat grassy field under a partly cloudy sky.

What you can check yourself

Keep the area around the outdoor unit clear. Grass clippings, leaves and dryer lint can build up on the coil fins and block airflow, and a plant growing in too close does the same thing. Check the air filter and swap it when it looks gray or clogged. A dirty filter makes the system work harder and can let the coil ice up. After a storm, take a look at the unit for bent fan blades or dents in the housing, and don't run it if the fan looks like it's hitting something. If you ever see ice on the copper lines or hear a new rattle or squeal, shut the system off and have it looked at rather than letting it keep running.

The charge gets checked, not guessed

A system can be low on refrigerant and still blow cold air at the vent, just not as cold as it should. Gauges on the lines show the charge is off before you'd ever notice the house struggling to cool.

The capacitor gets tested under load

A weak capacitor can still start the compressor and fan most of the time, right up until the morning it doesn't. A meter reading catches the weak one before it leaves you without cooling.

Aerial view of a gray outdoor air conditioning condenser unit mounted on a concrete pad next to a house with vinyl siding.

Book your AC tune-up in May, before homes here start needing cooling in June.

  1. Jan
  2. Feb
  3. Mar
  4. Apr
  5. May
  6. Jun
  7. Jul
  8. Aug
  9. Sep
  10. Oct
  11. Nov
  12. Dec

A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.

A real tune-up starts outside at the condenser. The tech pulls the top or side panel and washes the coil fins from the inside out, so the dirt that's packed in there goes out instead of deeper into the fins. Bent fins get combed back open because a crimped fin blocks air same as dirt does. The fan motor gets checked for play in the bearing and the blade gets looked at for a wobble, since a blade spinning off balance will wear the motor out early. Inside, the tech checks the blower wheel for dust buildup and makes sure the drain line isn't clogged, because a blocked drain backs up and can shut the system off on its own. Every electrical connection at the disconnect and the contactor gets snugged down, since a loose one arcs and burns before it ever trips a breaker.