A large outdoor air-conditioning unit mounted beside a vinyl-sided house, surrounded by mulched garden beds and green shrubs.

Heat Pump Repair in Fort Collins, CO

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpLarimer County, CO
Step 1 of 2

What ZIP code is the job in?

Winters here are not unusual for a heat pump

Larimer County averages 15°F on winter nights. That is normal cold-climate territory, nothing extreme for a heat pump built to run in it. Hail and wind show up often in this county too, and a bad storm can dent a cabinet or bend the fins on the outdoor unit. None of that means the heat pump is weak or wearing out ahead of schedule.

So look for the usual cause

A heat pump acting up is most likely a dirty filter, a low refrigerant charge, a failing capacitor, or a reversing valve stuck in one position. A contractor can check these in one visit. They can also tell you whether a storm played any part or whether a part simply wore out from normal use.

10 months
September through June, your system heats
15°F
the average winter night it heats against
76°F
the average summer afternoon it cools against
Isometric illustration of a cutaway single-family house showing interior ductwork and an air handler, with an outdoor condenser unit connected by lines along the exterior wall.

Heat pumps here start running in September and keep going through June.

The first cold snap in September puts load on a part that was already weak, so that is when repair calls spike.

A heat pump running on Fort Collins power costs you more for every day it runs broken

Power costs 14.92 cents a kWh statewide
102 damaging wind events from 2015 to 2024
155 hail events from 2015 to 2024

Half the homes in Larimer County were built in 1993 or later. If your house is one of them, the heat pump likely isn't old enough to be failing from age alone. A newer unit can still trip up on a stuck reversing valve or a weak capacitor, the same as any machine with moving parts. But that's a specific failure, not the system wearing out. That difference is what makes repair the right call most of the time. Worth checking the install date if the system came with the house.

Find out what's actually wrong, then get it fixed

Larimer County sees its share of hail, wind and winter storms, same as a lot of Colorado counties. That's not what takes down a heat pump. A stuck reversing valve or a weak capacitor doesn't wait for bad weather to fail. Get the actual cause checked now and most repairs are a single visit.

Find a contractor
A man in a dark knit hat, navy long-sleeve shirt and tan work pants walks up painted wooden porch steps toward an orange front door, carrying a canvas tool bag.
A gray heat pump outdoor unit mounted on a concrete pad next to a residential house with lap siding and stone accents.

What to check before you call

Before anyone comes out, go outside and look at the unit. Clear away leaves, ice or anything blocking the sides so air can move through the coil. Check the air filter inside and swap it if it's gray with dust. Look at the outdoor coil fins for ice buildup that doesn't go away after the unit runs its defrost cycle. Check the thermostat is set to heat and the batteries aren't dead. Check the breaker if the unit won't turn on at all. None of this fixes a stuck reversing valve or a weak capacitor, but it rules out the simple stuff first and gives the tech a clearer picture when they arrive.

It's blowing air that isn't warm or cold

A heat pump stuck on air temperature means the system isn't moving refrigerant the way it should. The reversing valve could be stuck between modes, or the charge could be low. Either way the unit is running but not actually heating or cooling, which wastes power and leaves rooms cold.

It's cycling on and off in short bursts

A heat pump that shuts off a few minutes after starting is protecting itself from something, usually restricted airflow or a part overheating. A dirty filter or blocked coil can cause this, but so can a failing capacitor or compressor. Short cycling wears out parts faster the longer it goes unchecked.

A weak capacitor forces the compressor to draw more current every time it tries to start, and that extra strain wears down the windings a little more each cycle. A low refrigerant charge makes the compressor work on a mix of liquid and gas it was never built to handle, and running it that way can score the internal parts. A stuck reversing valve can make the compressor push refrigerant against itself instead of where it needs to go. None of these fix themselves by running longer. The compressor is the one part in the system a tech cannot repair on site, only replace, so catching the problem early usually means dealing with a smaller part instead.

A heat pump rarely needs replacing just because one part fails. A capacitor, a contactor, a reversing valve, these are small parts that wear out on their own schedule and get swapped without touching the rest of the system. What changes the math is the compressor. It costs enough on its own that paying for it, plus labor, starts to rival a new system, especially if the rest of the unit has some years on it already. Age matters too, but less than how the system has been maintained. A unit that's had regular filter changes and a tech checking the charge every so often tends to fail part by part, which keeps favoring repair. One that's been neglected tends to fail all at once, which is when replacement starts to make more sense.